  • Hermetically Sealed (probe only)
  • Narrow differential between open and close set points
  • Snap-action switching
  • Pre-set, non-adjustable calibration
  • High resistance to shock and vibration
  • Qualified to MIL-PRF-24236/25

Specifications

Contact Resistance 0.100 ohms per MIL-STD-202, Method 307
Contact resistance shown is for the M2 thermostat and does not include resistance of wire leads or connector.
Dielectric Strength 1250 VAC, rms, 60 cycles for 1 minute, per MIL-STD-202, Method 301
Salt Spray Resistance Per MIL-STD-202, Method 101, Condition B, 5% Solution
Ambient Temperature Range -65°F to 400°F (-53.9°C to 204.4°C)
Maximum ambient exposure should be limited to 100°F above operating temperature for close on rise devices or 100°F below the operating temperature for open on rise devices.
Operating Temperature Range 0°F to +240°F, (-17.8°C to 115.6°C)