The ME Series Inverter / Charger from Sensata | Magnum Dimensions is a modified sine wave inverter designed specifically for rugged mobile applications. The ME Series is powerful, easy-to-use, and best of all, cost effective.
Safe and reliable: The ME Series is ETL Listed to the stringent requirements of UL/cUL 458 and CSA C22.2 #107.1-01, ensuring that the inverter is safe and reliable.
Part #ME2512 (ME2512-U)
Contact us to request pricing, availability and customization options
Contact Us
|
ME2012 |
ME2512 |
ME3112 |
Input battery voltage range |
9 - 16 VDC |
9 - 16 VDC |
9 - 16 VDC |
Nominal AC output voltage |
120 VAC ± 5% |
120 VAC ± 5% |
120 VAC ± 5% |
Output frequency and accuracy |
60 Hz ± 0.1 Hz |
60 Hz ± 0.1 Hz |
60 Hz ± 0.1 Hz |
1 msec surge current (amps AC) |
60 |
100 |
120 |
100 msec surge current (amps AC) |
37 |
45 |
50 |
5 sec surge power (real watts) |
3700 |
5000 |
6000 |
30 sec surge power (real watts) |
3450 |
4500 |
4800 |
5 min surge power (real watts) |
3100 |
3500 |
3950 |
30 min surge power (real watts) |
2400 |
2900 |
3500 |
Continuous power output at 25° C |
2000 VA |
2500 VA |
3100 VA |
Maximum continuous input current |
266 ADC |
333 ADC |
413 ADC |
Inverter efficiency (peak) |
95% |
91% |
90% |
Transfer time |
16 msecs |
16 msecs |
16 msecs |
Search mode (typical) |
5 watts |
5 watts |
5 watts |
No load (120 VAC output, typical) |
20 watts |
23 watts |
25 watts |
Waveform |
Modified Sine Wave |
Modified Sine Wave |
Modified Sine Wave |
|
ME2012 |
ME2512 |
ME3112 |
Continuous output at 25° C |
100 ADC |
120 ADC |
160 ADC |
Charger efficiency |
85% |
85% |
85% |
Power factor |
> .95 |
> .95 |
> .95 |
Input current at rated output (AC amps) |
15 |
18 |
22 |
Transfer relay capability | 2 legs at 30 A for 120 V/30 A or 240 V/60 A service |
Five stage charging capability | Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™ |
Battery temperature compensation | Yes, 15 ft Battery Temp Sensor standard |
Internal cooling | 0 to 120 cfm variable speed drive using dual 92mm brushless DC fans |
Overcurrent protection | Yes, with two overlapping circuits |
Overtemperature protection | Yes on transformer, MOSFETS, and battery |
Corrosion protection | Yes, PCB’s conformal coated, powder coated chassis/top, and stainless steel fasteners |
Dual AC branch rated output breakers | Optional on the ME2012 - AC breakers in 20 amp ratings |
Listings | ETL Listed to UL/cUL 458, CSA C22.2 #107.1-01 |