The H38 is an explosion proof version of the field-proven H25 encoder series. The H38 is UL certified for NEMA Class 4X and 6 (outdoor nonhazardous locations) and Class 4X and 13 (indoor non-hazardous locations). It is available with single and triple certifications for use in hazardous locations and includes a standard shaft seal, double bearing seals, and a cast aluminum housing with hard anodized and dichromate sealed finish. The H38 is suitable for use in petroleum service industries, solvent refining operations, spray painting applications, and explosive dust environments.
Contact us to request pricing, availability and customization options
Contact UsShaft Diameter | 3/8” nominal |
Shaft Loading | Up to 40 pounds axial and 20 pounds radial applied 1/4” from housing |
Shaft Runout | 0.0005 T.I.R |
Starting Torque at 25°C | 4.0 in-oz (max) |
Bearings | Class ABEC 7 standard |
Shaft Material | 303 stainless steel |
Enclosure | Die cast aluminum, hard anodized with dichromate sealed finish. Shaft seals and sealed bearings are standard to achieve environmental ratings. |
Bearing Life | 2 X 108 revs (1300 hrs at 2500 RPM) at rated load; 1 X 1010 revs (67,000 hrs at 2500 RPM) at 10% of rated load |
Maximum RPM | 10,000 RPM |
Moment of Inertia | 4.1 X 10-4 oz-in-sec2 UL & MSHA/ 1.7 X 10–3 oz-in-sec2 CEN |
Weight | 64 oz typical (approx 4 lbs) |
Code | Incremental |
Output Format | 2 channels in quadrature, 1/2 cycle index gated with negative B channel |
Cycles per Shaft Turn | 1 to 72,000 (see table 2, page 5). For resolutions above 3,600 see Note 7. |
Supply Voltage | 5 to 28 VDC |
Current Requirements | 100 mA typical +output load, 250 mA (max) |
Voltage/Output | 15V/V: Line Driver, 5–15 VDC in, Vout = Vin 28V/V: Line Driver, 5–28 VDC in, Vout = Vin 28V/5: Line Driver, 5–28 VDC in, Vout = 5 VDC 28V/OC: Open Collector, 5–28 VDC in, OCout |
Protection Level | Reverse, overvoltage and output short circuit (see note 3) |
Frequency Response | 100 KHz Typical, Higher frequency response available, see note 5 |
Termination Type | Compression type, UL recognized. Accepts AWG 14 to 22, stranded wire, strip 1/4” |
Note | Consult factory for other electrical options |
Enclosure Rating | NEMA 4 X & 6 (IP66), outdoor Non-Hazardous locations, NEMA 4 X & 13 (IP66), indoor Non-Hazardous locations |
Temperature | Standard operating all models, 0° to +70°C; Storage all models, -50° to +90°C; Extended temp testing avail.: for UL, -40° to +80°C; for CEN, -50° to +90°C |
Shock | 50 g’s at 11 msec |
Vibration | 5 to 2000 Hz @ 20 g’s |
Humidity | 100% RH |
Hazardous Area Rating | UL listed for use in hazardous locations. Class I, Group D, or Class I, Groups C & D, and Class II,Groups E, F & G. NEMA Enclosure 7. |