The H38 absolute is an explosion proof version of the field-proven H25 encoder series. The H38 is UL certified for NEMA Class 4X and 6 (outdoor non-hazardous locations) and Class 4X and 13 (indoor non-hazardous locations). It is available with single and triple certifications for use in hazardous locations and includes a standard shaft seal, double bearing seals, and a cast aluminum housing with hard anodized and dichromate sealed finish. The H38 absolute encoder is suitable for use in petroleum service industries, solvent refining operations, spray painting applications, and explosive dust environments. When your application needs the ability to recover position information quickly after a power loss and you are operating in a hazardous area—the H38 may be the answer to your needs.
Contact us to request pricing, availability and customization options
Contact UsShaft Diameter | 3/8” nominal |
Flats On Shaft | Two flats, 0.80” long X 0.30” deep at 90º |
Shaft Loading | Up to 40 pounds axial and 20 pounds radial applied 1/4” from housing |
Shaft Runout | 0.0005 T.I.R |
Starting Torque at 25°C | 4.0 in-oz (max) |
Bearings | Class ABEC 7 standard |
Shaft Material | 303 stainless steel |
Enclosure | Die cast aluminum, hard anodized with dichromate sealed finish. Shaft seals and sealed bearings are standard to achieve environmental ratings. |
Bearing Life | 2 X 108 revs (1300 hrs at 2500 RPM) at rated load; 1 X 1010 revs (67,000 hrs at 2500 RPM) at 10% of rated load |
Maximum RPM | 10,000 RPM |
Moment of Inertia | 4.1 X 10-4 oz-in-sec2 |
Weight | 64 oz typical (approx 4 lbs) |
Code | 12 or 13 bits NB or GC; excess gray and BCD available |
Counts per Shaft Turn | 4096 or 8192 |
Count Transition Accuracy | ± 1/2 bit maximum |
Supply Voltage | 5 to 28 VDC |
Current Requirements | 120 mA typical |
Output Formats | Parallel: Gray Code, Natural Binary and Binary Coded Decimal; Serial: Serial Synchronous Interface (SSI); Analog: 4–20 mA, 0–10V |
Voltage/Output | 28V/V: Line Driver, 5–28 VDC in, Vout = Vin 28V/5: Line Driver, 5–28 VDC in, Vout = 5 VDC 28V/OC: Open Collector, 5–28 VDC in OCout SSI: 5–28 VDC in/5Vout |
Protection Level | Reverse, overvoltage and output short circuit protection |
Frequency Response | 100kHz (1200 RPM for 12-bits, 600 RPM for 13-bits) |
Enclosure Rating | NEMA 4 X & 6 (IP66), outdoor Non-Hazardous locations, NEMA 4 X & 13 (IP66), indoor Non-Hazardous locations |
Temperature | Standard operating all models, 0° to +70°C; Storage all models, -50° to +90°C; Extended temp testing avail.: for UL, -40° to +80°C; for CEN, -50° to +90°C |
Shock | 50 g’s at 11 msec |
Vibration | 5 to 2000 Hz @ 20 g’s |
Humidity | 100% RH |
Hazardous Area Rating | Underwriters Laboratories listed for use in hazardous locations; NEMA Enclosure 7. Class 1, Group C & D, Division 1, NEC Class 2 circuits only, or Class 2, Groups E, F, and G. |