Distributors Stock

Need more information?

Contact us to request pricing, availability and customization options

Contact Us

Specifications

Output signal TTL Differential A Quad B
Accuracy / meter +/- 0.0002" (+/- 5 μm)
Resolutions 10 μm, 5 μm, 2 μm, 1 μm, 0.5 μm, 0.2 μm, or 0.1μm
Scale travels 2" to 40" (51 mm to 1,016 mm)
Scale diameter 0.226" (5.75 mm)
Reader head dimensions 1.38"H x 2.95"L x 0.98"D (35 mm x 75 mm x 24 mm)
Reference marker Every 0.19" (5 mm)
Equivalent line count / inch 635, 1270, 3175, 6350, 12700, 31750
Maximum traverse rate 65.6' (20m) / second (10μm), pro-rated to resolution
Power supply 5 VDC +/- 5%, < 80 mA
Shock (11 ms) 100g (IEC 69-2-6)
Vibration (55-2000 Hz) 30g (IEC 68-2-27)
Sample period 100 μs
Environmental rating IP67, fully submersible (IEC 529) - exceeds NEMA 6
Operating temperature 32°F to 131°F (0°C to 55°C)
Coefficient of expansion 12 x 10-6 K
Scale material Carbon fiber
Overall scale length Scale travel length + 7.4" (187 mm)
Standard cable 9 core, 11.5' (3.5 m) armored
Maximum cable length 72.2' (22 m)
Standard connector 9 pin "D" type
EMC compliance BS EN 50081-2 and BS EN 61000-6-2

 

Resolutions Custom resolutions available
Non-armored cable PUR (polyurethane)
Connectors
  • Honda PCR-E20FS (Fanuc)
  • IP67 (NEMA 6)
  • None (flying lead)
Cable lengths 22' (7m) or 19.68" (0.5m)

Related Resources