The SHG-VP linear encoder is intended for use with the SCC-200 module. The SCC-200 will output a ~1Vpp sine/cosine signal with a periodic reference marker.
Contact us to request pricing, availability and customization options
Contact UsOutput signal | ~1 Vpp sinusoidal from SCC-200 converter |
Accuracy / meter | +/- 0.0004" (+/- 10 μm) |
Resolution from the SCC-200 | 20 μm signal period |
Scale travels | 2" to 462" (51 mm to 11.73 m) - Travels over 462" available |
Scale diameter | 0.601" (15.25 mm) |
Reader head dimensions | 2.05"H x 5.16"L x 1.10"D (52 mm x 131 mm x 28 mm) |
Reference marker | Every 0.5" (12.7 mm) |
Power supply | 5 VDC +/- 5%, < 300 mA (with SCC-200) |
Shock (11 ms) | 100g (IEC 69-2-6) |
Vibration (55-2000 Hz) | 30g (IEC 68-2-27) |
Sample period | 100 μs |
Environmental rating | IP67, fully submersible (IEC 529) - exceeds NEMA 6 |
Operating temperature | 32°F to 131°F (0°C to 55°C) |
Coefficient of expansion | 12 x 10-6 K |
Scale material | 316 stainless steel |
Overall scale length | Scale travel length + 10.2" (258 mm) |
Standard cable | 9 core, 11.5' (3.5 m) armored |
Maximum cable length | 72.2' (22 m) |
Standard connector | 9 pin "D" type |
EMC compliance | BS EN 50081-2 and BS EN 61000-6-2 |
Resolutions | Custom resolutions available |
Non-armored cable | PUR (polyurethane) |
Connectors |
|
Cable lengths | 22' (7m) or 19.68" (0.5m) |