The SHG-VS linear encoder is intended for use with the SCC-200 module. The SCC-200 will output a ~1Vpp sine/cosine signal with a single reference marker. The encoder has a series of four selectable reference markers spaced every 25.4mm. The reference selected for the output reference is dependent on the rotational alignment of the scale relative to the reader head upon installation.
Contact us to request pricing, availability and customization options
Contact UsOutput signal | ~1 Vpp sinusoidal from SCC-200 converter |
Accuracy / meter | +/- 0.0004" (+/- 10 μm) |
Resolution from the SCC-200 | 20 μm signal period |
Scale travels | 2" to 462" (51 mm to 11.73 m) |
Scale diameter | 0.601" (15.25 mm) |
Reader head dimensions | 2.05"H x 5.16"L x 1.10"D (52 mm x 131 mm x 28 mm) |
Reference marker | Single (select 1 of 4) |
Power supply | 5 VDC +/- 5%, < 300 mA (with SCC-200) |
Shock (11 ms) | 100g (IEC 69-2-6) |
Vibration (55-2000 Hz) | 30g (IEC 68-2-27) |
Sample period | 100 μs |
Environmental rating | IP67, fully submersible (IEC 529) - exceeds NEMA 6 |
Operating temperature | 32°F to 131°F (0°C to 55°C) |
Coefficient of expansion | 12 x 10-6 K |
Scale material | 316 stainless steel |
Overall scale length | Scale travel length + 10.2" (258 mm) |
Standard cable | 9 core, 11.5' (3.5 m) armored |
Maximum cable length | 82' (25 m) |
Standard connector | 9 pin "D" type |
EMC compliance | BS EN 50081-2 and BS EN 61000-6-2 |
Resolutions | Custom resolutions available |
Non-armored cable | PUR (polyurethane) |
Connectors |
|
Cable lengths | 22' (7m) or 19.68" (0.5m) |