Industrial inclinometers are typically used for determining the inclination or tilt of a platform or controlled surface with remarkable precision. The molded housing provides mechanical stability and the fully encapsulated sensor has a high environmental protection making it ideal for measuring tilt / slope in industrial environments. The synchronous serial interface (SSI) with its RS422 differential line drivers allows transmission cable length up to 1200m. The simple and standard SSI protocol makes it easy to connect the sensor to common PLC systems or embedded controllers.
Applications: Cranes and construction machines; robotic arms & positioning systems; mobile platforms; solar trackers; medical systems.
Contact us to request pricing, availability and customization options
Contact UsHousing Material | Glass Fiber Reinforced PBT (Polybutylene Terephthalate) (UV-Stabilized, UL 94-V0 Standard) |
Potting Material | PUR (Polyurethane) |
Weight | 75 gm [3 oz] |
Model | T-P1-360-S3-XX | ||||
Measurement Range | 360° | ||||
Number of Axes | 1 | ||||
Resolution | 13 Bit (0.04°)1 | ||||
Accuracy | 0.14° | ||||
Sensor Response Time | 100ms ± 10%1 | ||||
Interface | Synchronous Serial Interface (SSI) | ||||
Current Consumption | <250mA at 5V DC, <100 mA at 10 V DC, <80 mA at 24 V DC | ||||
Power Consumption | Бelow 1.5 W | ||||
Clock Input | Via Оpto-coupler | ||||
Data Output | Line-driver according to RS 422 | ||||
Clock Frequency | 100 kHz – 2 MHz | ||||
Supply Voltage | 4.5 – 30 V DC (absolute maximum ratings)2 | ||||
Turn on Time | < 1 s | ||||
EMC | Emitted Interference: EN 61000-6-4 Noise Immunity: EN 61000-6-2 |
Operating Temperature | -40 °C to +85 °C / -40 °F to 185 °F |
Protection Class (EN 60529) | IP 69K & IP68 (With Appropriate Mating Connector) |
Shock (EN 60068-2-27) | ≤100 g (half sine, 6 ms) |
Vibration (EN 60068-2-6) | 1.5mm (10 to 58 Hz) ≤20 g (58 to 2000 Hz |