Distributors Stock

Part #TCW400-3600-001

Need more information?

Contact us to request pricing, availability and customization options

Contact Us

Features

  • With its two-part design, the TCW4 absolute multi-turn offers maximum flexibility for installation
  • Rugged and excellent resistance to shock and vibration
  • Robust, proven magnetic technology
  • Environmentally resistant, IP 67 standard (IP69K option)
  • Extended operating range from -20° C to 85° C
  • Uses universal supply 5 to 30 VDC – Analog output
  • Available Resolution up to 12 bits per turn with up to 16 bits of turns counting
  • Variety of magnet holders available

Specifications

Terminations PUR cable with M12 5 pin connector
Housing Macromelt PA638
Weight 0,150 kg
Electrical Angle 360°
Output Function 0– 10 Vdc, 0.5 to 4.5 Vdc, or 4 – 20 mA
Minimal Cycle Time 1 ms
Resolution Multi-turn, 12 bits per turn with up to 10 turns of turns counting
Accuracy +/-0.3% on 360°
Repeatability +/-0.1% on 360°
Supply Voltage 5-30 Vdc or 15-30 Vdc
Start-up < 1s
Response time < 10 ms (5L2 and 3L1 electronics), <1ms (All other electronics)
Recommended Load > 10 kOhms (voltage out), 500 Ohms (current out)
Current Requirements < 40mA
Protection Overvoltage Protection: Yes
Reverse Polarity Protection: Yes
Short Circuit Protection: Yes
EMC IEC 61000-4-2 Electrostatic discharge (ESD) 4 kV, 8 kV
IEC 61000-4-3 Electromagnetic fields 10 V/m (80MHz - 1GHz), 3V/m (1.4GHz - 2GHz), 1V/m (2GHz - 2.7GHz)
IEC 61000-4-4 Electrical fast transients (burst) 1 kV
IEC 61000-4-6 Conducted disturbances, induced by RF-fields 10 Veff.

 

Related Resources