Contact us to request pricing, availability and customization options
Contact UsApplications
Operating Life Cycle | min. 10 million full pressure cycles over the full range |
Vibration Resistance | IEC 60068-2-64 (RANDOM) 20 PSD |
Shock Resistance | 100 g minimum according to DIN EN 60068-2-27 |
Drop Test | 1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1 |
Weight | ≤ 50 grams |
Ingress Protection | IP 65 or IP67 - depending on electrical connector |
Medium Temperature | -30°C to + 120°C (others on request) |
Environmental Temperature | -30°C to + 100°C (depending on internal and external seal ring capability) |
Storage Temperature | -30°C to + 100°C (depending on internal and external seal ring capability) |
Media | All class II fluids and gases compatible with stainless steel 304 (1.4301) and the internal and external (optional) seal ring material |
Accuracy | ≤ 1 % of span 4 |
Non-linearity | 0.2 % of span 4 |
Non-repeatability | 0.1 % of span 4 |
1-year stability | 0.2 % of span 4 |
Temp. Coefficients - Zero | 0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 % |
Temp. Coefficients - Span | 0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 % |
Output Signal | 4…20 mA | 0.5…4.5 VDC ratiometric | 0…5 VDC | 0…10 VDC |
Operating Supply Signal | 9-30 VDC | 5 VDC ± 5% | 8-30 VDC | 14-30 VDC |
Power Consumption | ≤ 600 mW | ≤ 25 mW | ≤ 600 mW | ≤ 600 mW |
Overvoltage Protection | min. 33 VDC | min. 33 VDC | min. 33 VDC | min. 33 VDC |
Short-circuit Proofness | not applicable | Yes | Yes | Yes |
Insulation Voltage | 500 VDC | 500 VDC | 500 VDC | 500 VDC |
Reverse Polarity Protection | Yes | Yes | Yes | Yes |
Load | ≤ (Vsup-8 VDC)/(0.02 A) [Ω] | ≥ 4.7 kΩ | ≥ 4.7 kΩ | ≥ 4.7 kΩ |
Response Time | ≤ 5 ms max. to 63% of full scale pressure with step change on input |