Specifications

Control Voltage 60V, 3 A 60V, 6 A 60V, 12 A 100V, 3 A 100V, 6 A 100V, 10A 100V, 12A 100V, 24 A
4-32 VDC DR06D03 DR06D06 DR06D12 DR10D03 DR10D06 DR10D10 DR10D12 DR10D24
Description DR06D03 DR10D03 DR06D06 DR10D06 DR10D10 DR06D12 DR10D12 DR10D24
Operating Voltage [VDC]  1-60 1-100 1-60 1-60 1-100 1-60 1-60 1-100
Maximum Load Current [Adc]   3 3 6 6 10 12 12 24
Minimum Load Current [mAdc]  2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Maximum On-State Voltage Drop @ Rated Current [Vpk]  0.6 0.6 0.6 0.6 0.2 0.6 0.6 0.2
Maximum Surge Current (10ms) [Apk]  60 60 60 60 80 100 100 160
On-State resistance at rated current [Ohms] 0.6 0.6 0.1 0.1 0.013 0.45 0.45 0.026
Min/Max stranded wire  22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG
Min/Max solid wire  22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG
Weight (Typical) 1.76 oz (50g) 1.76 (50g) 1.94 (55g) 1.76 (50g) 1.76 (50g) 3.17 oz (90 g)
3.17 oz (90 g)
3.17 oz (90 g)
Control Voltage Range 4-32 VDC
Minimum Turn-On Voltage 4.0 VDC
Must Turn-Off Voltage 1.0 VDC
Minimum Input Current for [mA]  9
Maximum Input Current for [mA]  11
Maximum Turn-on Time [msec]  0.6
Maximum Turn-off Time [msec] 0.3
Min/Max stranded/solid wire 22/16 AWG
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 2500 Vrms
Minimum Insulation Resistance (@ 500 V DC) 109 Ohms
Maximum Capacitance, Input/Output  10 pF
Ambient Operating Temperature Range -30 to 80 °C
Ambient Storage Temperature Range -30 to 100 °C
Recommended Terminal Screw Torque Range 4.4-7.0 lb-in (0.5-0.8 Nm)
Series Operating Voltage Control Voltage Rated Load Current ATEX Approvals
DR 06: 1-60 VDC
10: 1-100 VDC
D: 4-32 VDC 03: 3 Amps
06: 6 Amps
10: 10 Amps (100 VDC only)
12: 12 Amps
24: 24 Amps (100 VDC only)
Blank: Not ATEX approved
X: ATEX II 3G Ex nA IIC T4 Gc approved (3, 6 and 12 Amps only)

Related Resources