The 5100 series is a single pole, single throw, snap-action, hermetically sealed temperature control designed for applications requiring high vibrational resistance in an isolated case.
The snap-action disc is located in the very tip of the probe, assuring rapid and true response to temperature. The welded construction of this sealed thermostat ensures meeting thermal shock specifications of MIL-STD-202, method 107, test condition B. In addition, the tube will withstand a pressure exposure limit of 1500 PSI.
Part #051AAA245A-225Y
Contact us to request pricing, availability and customization options
Contact UsContact Ratings | Cycles 100,000 100,000 6,000 |
Voltage 120VAC / 32 VDC 125VAC pilot duty to 240VAC 240VAC |
Amps 3 (resistive) 1.5 (resistive) 2.5 (resistive) |
Case Type isolated case isolated case isolated case |
Contact Operations | Either close on rise (make) or open on rise (break), SPST (Single Pole, Single Throw) | |||
Operating Temperature | +35ºF to 480ºF (+1.67ºC to 249ºC) | |||
Dielectric Strength | 1800 Vrms, 60Hz terminals to case | |||
Insulation Resistance | 60 megaohms at 500 VDC | |||
Vibration | .06DA, 10-55 Hz, 20G 20-2000 Hz | |||
Shock | .75G 6ms duration (sawtooth) | |||
Pressure Exposure Limit | Standard tube will withstand 1500 psi max | |||
Approvals | UL E36687 and E66685, CSA LR25561-6 and LR25561-8 | |||
Material | Stainless steel body and tube, compression glass seal, Mylar® sleeve, epoxy fill potting, stainless orplated steel terminals, fine silver contacts |
Contact Operation | Family | Terminal Selection | Mounting Thread Selection | Tube Length Selection | Top Temperature (in °F) | Top Temperature Tolerance Code | Bottom Temperature (in °F) | Bottom Temperature Tolerance Code |
O, C See Contact Operation Table |
5100 Series |
A, B, C, D, E, F See Terminal Selection Table |
A, B, C, E, F See Mounting Thread Selection Table |
A, B, C See Tube Length Table |
See Temperature Code and Tolerance Table |
A, C, N See Temperature Codes and Tolerance Table (Available in Increments of 5°F) |
See Temperature Codes and Tolerance Table |
A, C, N, Y See Temperature Codes and Tolerance Table |