Application Note: GVL 24V Set/Reset Voltage and Coil Current vs. Temperature
Since Gigavac contactors are operated by a coil that changes resistance with temperature, Pickup Voltage and Drop Out Voltage will decrease at temperatures below 25C and increase at temperatures ab
Learn MoreApplication Note: GX11B, GX12B, and GX21B Temperature Considerations
Since Gigavac contactors are operated by a coil that changes resistance with temperature, Pickup Voltage and Drop Out Voltage will decrease at temperatures below 25C and increase at temperatures ab
Learn MoreApplication Note: GX11C, GX12C, and GX21C Temperature Considerations
Since Gigavac contactors are operated by a coil that changes resistance with temperature, Pickup Voltage and Drop Out Voltage will decrease at temperatures below 25C and increase at temperatures ab
Learn MoreApplication Note: GX14B, GX200B, GX23B, HX200B and HX21B Temperature Considerations
Since Gigavac contactors are operated by a coil that changes resistance with temperature, Pickup Voltage and Drop Out Voltage will decrease at temperatures below 25C and increase at temperatures ab
Learn MoreApplication Note: GX14C, GX200C, GX23C, HX200C and HX21C Temperature Considerations
Since Gigavac contactors are operated by a coil that changes resistance with temperature, Pickup Voltage and Drop Out Voltage will decrease at temperatures below 25C and increase at temperatures ab
Learn MoreApplication Note: GX16B and HX22B Temperature Considerations
Since Gigavac contactors are operated by a coil that changes resistance with temperature, Pickup Voltage and Drop Out Voltage will decrease at temperatures below 25C and increase at temperatures ab
Learn MoreApplication Note: GX16C and HX22C Temperature Considerations
Since Gigavac contactors are operated by a coil that changes resistance with temperature, Pickup Voltage and Drop Out Voltage will decrease at temperatures below 25C and increase at temperatures ab
Learn MoreApplication Note: GXNC14B Temperature Considerations
Since Gigavac contactors are operated by a coil that changes resistance with temperature, Pickup Voltage and Drop Out Voltage will decrease at temperatures below 25C and increase at temperatures ab
Learn MoreApplication Note: GXNC14C Temperature Considerations
Since Gigavac contactors are operated by a coil that changes resistance with temperature, Pickup Voltage and Drop Out Voltage will decrease at temperatures below 25C and increase at temperatures ab
Learn MoreApplication Note: Hermetic Thermal Switches Used in Space Craft Thermal Control Systems
Thermal control systems are essential to keep all equipment within an acceptable temperature range throughout all mission phases on satellites, space rovers and manned space exploration vehicles.
Learn MoreApplication Note: Hydraulics and Pneumatics
Pneumatic technology is used in vehicle tires, air brakes of buses, trucks or trains, compressed-air engines, vacuum pumps, and more.
Learn MoreApplication Note: Inspecting, Packaging, Sorting and Palletizing with IO-Link
Packaging has some very complex automation needs: all the way from die-cutting, carton erecting, filling, inspecting, and closing, to multi-packing and palletizing.
Learn More