Distributors Stock

Need more information?

Contact us to request pricing, availability and customization options

Contact Us

Features

  • High performance MSG sense elements
  • Available with quad redundant outputs
  • Construction reduces EMC related issues
  • Proprietary ASIC technology for highly accurate, temperature compensated performance with diagnostic capability
  • Lightning and ESD protected
  • RTCA DO-160 and MIL-STD-810 tested

Specifications

Pressure Ranges

0-50 and 0-600 bar (0-725 and 0-8700 psi)

Pressure Reference

Gauge

Accuracy (Best Fit Straight Line)(a)

+/-0.25% FS @ 25 °C

Accuracy (Total Error Band)(b)

+/-4.0% FS @ -20 °C to +85 °C

Operating Endurance

>10 million cycles

Operating Ambient Temperature

-40 °C to +100 °C

Operating Media Temperature

-40 °C to +125 °C

Storage Temperature(c)

-40 °C to +125 °C

Supply Voltage / Output

8-32VDC for 4-20mA output

5±0.25VDC for 0.5-4.5VDC output

8-32VDC for 0-5VDC output

12-32VDC for 0-10VDC output

8-32VDC for 1-5VDC output

8-32VDC for 0.5-4.5VDC output

Output Load

≥ 4.7 kΩ for voltage output

≤ (Vsup-8)/20mA for current supply

Output Response Time

<2ms

Overvoltage Protection

36 VDC

Reverse Voltage Protection

Yes

Short Circuit Protection

Yes

Insulation Resistance

>100 MΩ at 500V

EMC

IEC 61326-1 and EN 61326-2-3

Dielectric

500VAC

Enhanced Radiate Immunity

100V/m (80-200MHz)

200V/m (200-2700MHz)

Enhanced ESD

+/-8KV Contact; +/-15KV Air

Max Operating Load ±200 lbf in pitch and roll ±65lbf coaxial to the Grip Axis
Ultimate Load ±375lbf pitch and roll ±100lbf coaxial to the Grip Axis
Random Vibration RTCA/DO-160G
Mechanical Shock RTCA/DO-160G
Drop (any axis) NA
Axes Part Series Redundant Outputs Sequential Dash Number
1 = Single
2 = Dual
PFS 1 = Single channel
2 = Dual channel
Sequential dash number assigned to
capture customer application requirements