Distributors Stock

Part #ACW400-12BT-006

Need more information?

Contact us to request pricing, availability and customization options

Contact Us

Features

  • With its two-part design, the ACW4 absolute single-turn offers maximum flexibility for installation
  • Rugged and excellent resistance to shock and vibration
  • Robust, proven magnetic technology
  • Environmentally resistant, IP 67 standard (IP69K option)
  • Extended operating range from -40° C to 85° C
  • Uses universal supply 5 to 30 VDC – SSI Output
  • Available Resolution up to 12 bits per revolution
  • Variety of magnet holders available

Specifications

Terminations PUR cable with M12 5 pin connector
Housing Macromelt PA638
Weight 0,150 kg

 

Electrical Angle 360°
Output Function SSI, 10% to 90% Duty Cycle, 2LP = 5Vdc; 5LP = 11 to 30 Vdc
Minimal Cycle Time 1 ms
Resolution Single–turn, 12 bits
Accuracy +/-0.3% on 360°
Repeatability +/-0.1% on 360°
Supply Voltage 5-30 Vdc
Start-up < 1s
Response time < 10 ms
Recommended Load > 10 kOhms
Isolation 500 Veff
Current Requirements < 40mA
Protection Overvoltage Protection: Yes
Reverse Polarity Protection: Yes
Short Circuit Protection: Yes
EMC IEC 61000-4-2 Electrostatic discharge (ESD) 4 kV, 8 kV
IEC 61000-4-3 Electromagnetic fields 10 V/m (80MHz - 1GHz), 3V/m (1.4GHz - 2GHz), 1V/m (2GHz - 2.7GHz)
IEC 61000-4-4 Electrical fast transients (burst) 1 kV
IEC 61000-4-6 Conducted disturbances, induced by RF-fields 10 Veff.