Distributors Stock

Need more information?

Contact us to request pricing, availability and customization options

Contact Us

Features

  • Dry Media
  • Superior Long Term Stability
  • Excellent Repeatability/Hysteresis
  • Superior EMI/RFI Rejection
  • Low Power Consumption
  • Linear Output
  • Temperature Compensated
  • Over-Voltage, Reverse Polarity & Short Circuit Protection
  • Ten Million Cycle Life Expectancy
  • Outstanding Shock & Vibration Performance

Applications

  • Steam Sterilizers
  • Gasoline & Diesel Engines
  • Natural Gas & CNG Engines
  • Agricultural Chemical Equipment
  • Level Measurement
  • Test Equipment
  • Injection Molding
  • Coolant Pressure
  • Industrial Compressors

Specifications

Operating Life Cycle min. 10 million full pressure cycles over the full range
Vibration Resistance 10 G's peak to peak sinusoidal (10 to 2000 Hz)
Shock Resistance 75 G’s ½ sinewave
Drop Test 1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
Weight . 100 grams (without mating connector)
Ingress Protection IP 65 or IP67 - depending on electrical connector
Operating Temperature -40°C to 125°C (depending on seal material)
Storage Temperature -40°C to 125°C (depending on seal material)
Media All class II fluids and gases compatible with stainless steel 303 and the internal seal ring material

 

Total error band +/-2% of span (-20 . T . 100‹ C) +/-3% of span (T < -20‹ C,T < 100‹ C)
Stability coefficient +/-0.5 % of full span over 1 year
Temp. Coefficients - Zero 0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
Temp. Coefficients - Span 0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %

 

Output Signal 0.5…4.5 VDC Ratiometric
Operating Supply Signal 5 VDC ± 10%
Power Consumption . 25 mW
Overvoltage Protection 16 VDC
Short-circuit Proofness Yes
Insulation Voltage 500 VDC
Reverse Polarity Protection Yes
Load ≥ 25 kΩ
Response Time 15 ms max. to 63% of full scale pressure with step change on input