Contact us to request pricing, availability and customization options
Contact UsOutput Signal | 0.5…4.5 VDC ratiometric |
Operating Supply Signal | 5 VDC ± 5% |
Power Consumption | ≤ 25 mW |
Overvoltage Protection | 16 VDC |
Short-circuit Proofness | Yes |
Insulation Voltage | 500 VDC |
Reverse Polarity Protection | Yes3 |
Output Load | ≥ 5 kΩ |
Response Time | ≤ 10 ms max. to 63% of full scale pressure with step change on input |
*3 for min. 10 seconds on assigned pins
RoHS | 2002/95/EC RoHS Directive |
CE | Pressure equipment directive 89 /336 /EEC, IEC/EN 61326-1: 2006, IEC/EN 61000-4-2: 2001, IEC/EN 61000-4-3: 2006, IEC/EN 61000-4-8: 2001. |