Part #116CP31-M04S2-50
Contact us to request pricing, availability and customization options
Contact UsSupply Voltage | 5VDC (ratiometric) or 8-30VDC (voltage regulated) |
Output Voltage | Commonly 0.5 to 3.5V or 0.5 to 4.5V (Others available under ordering options) |
Supply Current | 8.0mA |
Output Current | 5.0mA (max) |
Output Load | 10kOhm pull down |
Output Response Time | <10ms |
Overvoltage Protection | ±40V |
Reverse Voltage | -14V |
Short Circuit Protected | Up to 40V |
EMC | EMC Conforms to EN61326-2-3 for sensors |
ESD | Conforms to IEC 61000-4-2 Level 3, 4kV contact / 8kV air |
Pressure Ranges | 0-4 to 0-16bar (0-60 to 0-232 PSI) |
Proof Pressure | 2xFS (1) |
Burst Pressure | 3xFS (1) |
Random Vibration | DIN IEC 60068-2-27: 5G (2-2kHz) |
Mechanical Shock | DIN IEC 60068-2-6: 40G1/2 HL SINE |
Drop (any Axis) | 1 m |
Medium | Water* |
(1) FS (Pressure) = Pmax – Pmin.
*Other Media available upon consultation with Sensata.
Electrical Connection | RAST 2.5 (see ordering options in datasheet) |
Pressure Connection | G⅜, G¼, quick connect |
Pressure Reference | Sealed Gauge (1bar) |
Total Error Band Accuracy | +/-1.5%Vs (typical) (2) |
Operating Temperature | 2° to 90°C |
Storage Temperature | -40° to 115°C |
(2) Vs = Supply Voltage