MODELS 1202 / 1302 / 1502 / 1602 / 1702 / 1802 INDUSTRIAL MODELS 1232 / 1632
Contact us to request pricing, availability and customization options
Contact UsDescription | 1202 | 1302 | 1502 | 1602 | 1702 | 1802 | 1232 | 1632 |
Actual Electrical Travel | 354°±2° | 354°±2° | 354°±2° | 354°±1° | 354°±1° | 358°±1° | 354°±2° | 354°±2° |
Normal Resistance Range | 100Ω to 25K | 100Ω to 30K | 100Ω to 50K | 100Ω to 60K | 100Ω to 75K | 100Ω to 100K | 100Ω to 25K | 100Ω to 60K |
Extended Resistance Range | 15Ω to 75K | 25Ω to 100K | 25Ω to 125K | 25Ω to 150K | 25Ω to 200K | 25Ω to 250K | 15Ω to 50K | 25Ω to 100K |
Resistance Tolerance: Standard % | ±3 | ±5 | ||||||
Best Practical % | ±1 | |||||||
Power Rating At 70°C, Derating to 0 At 125°C (Watts) | 1.25 | 2.0 | 3.0 | 4.0 | 5.0 | 7.0 | 1.25 | 4.0 |
Linearity, Independent, Tolerance, Standard % | ±0.5 | ±0.4 | ±0.3 | ±0.25 | ±0.2 | ±0.15 | ±0.5 | ±0.3 |
Best Practical % | ±0.2 | ±0.15 | ±0.12 | ±0.09 | ±0.08 | ±0.05 | ±0.25 | ±0.15 |
Equivalent Noise Resistance (ENR) Max. (Ohms) | 100 | |||||||
End Voltage Max. (% Of Total Applied Voltage) | Within linearity tolerance | |||||||
Insulation Resistance At 500 VDC, Min. (Megohms) | 1000 | |||||||
Dielectric Withstanding Voltage (Volts RMS) | 1000 | |||||||
Max. Applied Voltage(Volts DC) | 400 | |||||||
Temperature Coefficient Of Potentiometer, Max. % / °C | ±.007 |